FINAL REPORT DURAMELTER 100 HLW SIMULANT VALIDATION TESTS WITH C-106/AY-102 FEEDS VSL-05R5710-1 REV 0 6/2/05 | |
AA, KRUGER ; KS, MATLACK ; W, GONG ; IL, PEGG | |
Hanford Site (Wash.) | |
关键词: Testing; Hydroxides; Processing; Wastes; 12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities; | |
DOI : 10.2172/1034770 RP-ID : ORP-51503 Rev 0 RP-ID : DE-AC27-08RV14800 RP-ID : 1034770 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The principal objectives of the DM100 tests were to determine the processing characteristics of several C-106/AY102 feeds derived from simulants prepared by different methods, which result in different physical characteristics of the feed. The VSL simulant used in a previous test was prepared by the direct hydroxide method, which was the method used for feed preparation in the bulk of previous VSL melter testing. The NOAH Technologies Corporation modified-rheology simulant was prepared to the same composition as the VSL simulant using a method that resulted in rheological properties closer to those of certain actual waste samples. The SIPP simulant was produced by processing a co-precipitated waste simulant through a non-radioactive pilot scale semi-integrated pretreatment facility. The general intent of these tests was to provide a basis for determining whether the variations in rheology or other feed physical characteristics arising from the different methods of simulant preparation have significant effects on the processing characteristics of the feed in the melter. Completion of the test objectives is detailed in a table.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
1034770.pdf | 5025KB | download |