Neutron Capture Cross Section Measurement on $^{238}$Pu at DANCE | |
Chyzh, A ; Wu, C Y | |
Lawrence Livermore National Laboratory | |
关键词: Lawrence Livermore National Laboratory; Lanl; Plating; Capture; Containment; | |
DOI : 10.2172/1026477 RP-ID : LLNL-TR-471080 RP-ID : W-7405-ENG-48 RP-ID : 1026477 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The proposed neutron capture measurement for {sup 238}Pu was carried out in Nov-Dec, 2010, using the DANCE array at LANSCE, LANL. The total beam-on-target time is about 14 days plus additional 5 days for the background measurement. The target was prepared at LLNL with the new electrplating cell capable of plating the {sup 238}Pu isotope simultaneously on both sides of the 3-{micro}m thick Ti backing foil. A total mass of 395 {micro}g with an activity of 6.8 mCi was deposited onto the area of 7 mm in diameter. The {sup 238}Pu sample was enriched to 99.35%. The target was covered by 1.4 {micro}m double-side aluminized mylar and then inserted into a specially designed vacuum-tight container, shown in Fig. 1, for the {sup 238}Pu containment. The container was tested for leaks in the vacuum chamber at LLNL. An identical container without {sup 238}Pu was made as well and used as a blank for the background measurement.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
1026477.pdf | 236KB | download |