科技报告详细信息
ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Determination Quantitative Analysis
Halverson, Mark A. ; Liu, Bing ; Richman, Eric E. ; Winiarski, David W.
Pacific Northwest National Laboratory (U.S.)
关键词: Buildings Ansi, Ashrae, Iesna, Quantitative, Standard 90.1-2007;    Heating;    Air Conditioning;    32 Energy Conservation, Consumption, And Utilization;    North America;   
DOI  :  10.2172/1025681
RP-ID  :  PNNL-20456
RP-ID  :  AC05-76RL01830
RP-ID  :  1025681
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The United States (U.S.) Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2004. The final analysis considered each of the 44 addenda to ANSI/ASHRAE/IESNA Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measureable and quantifiable impact.

【 预 览 】
附件列表
Files Size Format View
1025681.pdf 923KB PDF download
  文献评价指标  
  下载次数:22次 浏览次数:67次