R&D ERL: High power RF systems
Zaltsman, A.
Brookhaven National Laboratory. Collider-Accelerator Department.
关键词: Power Supplies;    Rf Systems;    43 Particle Accelerators;    Linear Accelerators;    Superconducting Cavity Resonators Relativistic Heavy Ion Collider;   
DOI  :  10.2172/1013459
RP-ID  :  BNL--91004-2010-IR
RP-ID  :  DE-AC02-98CH10886
RP-ID  :  1013459
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The Energy Recovery Linac (ERL) project, now under construction at Brookhaven National Laboratory, requires two high power RF systems. The first RF system is for the 703.75 MHz superconducting electron gun. The RF power from this system is used to drive nearly half an Ampere of beam current to 2.5 MeV. There is no provision to recover any of this energy so the minimum amplifier power is 1 MW. It consists of 1 MW CW klystron, transmitter and power supplies, 1 MW circulator, 1 MW dummy load and a two-way power splitter. The second RF system is for the 703.75 MHz superconducting cavity. The system accelerates the beam to 54.7 MeV and recovers this energy. It will provide up to 50 kW of CW RF power to the cavity. It consists of 50 kW transmitter, circulator, and dummy load. This paper describes the two high power RF systems and presents the test data for both.