科技报告详细信息
Report on First Activations with the Lead Slowing Down Spectrometer
Warren, Glen A. ; Mace, Emily K. ; Pratt, Sharon L. ; Stave, Sean ; Woodring, Mitchell L.
Pacific Northwest National Laboratory (U.S.)
关键词: Lead Slowing Down Spectrometer;    Slowing-Down;    Gamma Spectroscopy;    Spectrometers Activation;    Irradiation;   
DOI  :  10.2172/1012299
RP-ID  :  PNNL-20239
RP-ID  :  AC05-76RL01830
RP-ID  :  1012299
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

On Feb. 17 and 18 2011, six items were irradiated with neutrons using the Lead Slowing Down Spectrometer. After irradiation, dose measurements and gamma-spectrometry measurements were completed on all of the samples. No contamination was found on the samples, and all but one provided no dose. Gamma-spectroscopy measurements qualitatively agreed with expectations based on the materials, with the exception of silver. We observed activation in the room in general, mostly due to 56Mn and 24Na. Most of the activation was short lived, with half-lives on the scale of hours, except for 198Au which has a half-life of 2.7 d.

【 预 览 】
附件列表
Files Size Format View
1012299.pdf 1620KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:18次