科技报告详细信息
Modifications to the VV PHTS RELAP5 Model
Carbajo, Juan J
Oak Ridge National Laboratory
关键词: Modifications;    Vacuum Systems;    Power;    Heat Transfer;    Pipes;   
DOI  :  10.2172/1004970
RP-ID  :  ORNL/TM-2011/1
RP-ID  :  DE-AC05-00OR22725
RP-ID  :  1004970
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Modifications and improvements to a previous RELAP5 model of the Vacuum Vessel Primary Heat Transfer System are described in this report. The modifications were new pump models, a new steam pressurizer, new coolant water control systems, additional pipe structures, and reduction of the pulse power to 6 MW.

【 预 览 】
附件列表
Files Size Format View
1004970.pdf 2300KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:7次