科技报告详细信息
Two-Phase Loop: Compact Thermosyphon
Beitelmal, Monem H. ; Patel, Chandrakant D.
HP Development Company
关键词: liquid loop;    thermosyphon;    passive cooling loop;   
RP-ID  :  HPL-2002-6
学科分类:计算机科学(综合)
美国|英语
来源: HP Labs
PDF
【 摘 要 】

Power density of future microprocessors is projected to reach over 100 W/cm(superscripted 2). Shrinking system size, the need to integrate more components within limited space, and customer demand to reduce system acoustic noise present significant challenges to the thermal designer. Thermosyphon technology provides a promising solution to these thermal challenges. Conventional heat sink capability to overcome the new thermal challenges is limited. Refrigeration and spray cooling can provide a solution to the thermal challenges posed by the higher power density, however reliability issues are still unresolved making these solutions impractical for the current challenges. Loop thermosyphon provides the benefits of using liquid cooling for microprocessor. It is a two-phase passive cooling loop that uses liquid as a working fluid. The loop between the evaporator and the condenser results in separate vapor and condensate path. It is considered to be a compact thermal management device due to its flexibility in size and cooling capacity range. This report presents HP Laboratories loop thermosyphon prototype and the experimental results of its thermal performance. 22 Pages

【 预 览 】
附件列表
Files Size Format View
RO201804100002123LZ 332KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:5次