科技报告详细信息
Rayleigh Scattering Measurements Using a Tunable Liquid Crystal Fabry-Perot Interferometer
Elam, Kristie A. ; Clem, Michelle M. ; Mielke-Fagan, Amy F.
PID  :  NTRS Document ID: 20110016048
RP-ID  :  E-17950
学科分类:物理(综合)
美国|英语
来源: NASA Technical Reports Server
PDF
【 摘 要 】
Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, velocity, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of a tunable liquid crystal (LC) Fabry-Perot etalon in Rayleigh scattering experiments at NASA Glenn Research Center. The LC etalon provides a robust interferometry system that can be tuned rapidly by adjusting the voltage applied to the liquid crystal interface. Tuning the interferometer is often necessary to control the physical locations of the concentric interference fringes when Rayleigh light is imaged through the LC etalon. The LC etalon diagnostic system was tested in a 1-cm diameter nozzle flow in two different scattering configurations to evaluate its usefulness for Rayleigh measurements compared to a traditional non-tunable fused silica Fabry-Perot etalon.
【 预 览 】
附件列表
Files Size Format View
RO201712040005079LZ 960KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:5次