A Cryogenic Infrared Calibration Target | |
Rinehart, S. A. ; Kinzer, R. E., Jr. ; Wollack, E. J. | |
PID : NTRS Document ID: 20140016978 RP-ID : GSFC-E-DAA-TN15362 |
|
学科分类:原子、分子光学和等离子物理 | |
美国|英语 | |
来源: NASA Technical Reports Server | |
【 摘 要 】
A compact cryogenic calibration target is presented that has a peak diffuse reflectance, R < or = 0.003, from 800 to 4800/cm (12 - 2 microns ). Upon expanding the spectral range under consideration to 400-10,000/ cm-1 (25 - 1 microns) the observed performance gracefully degrades to R < or = 0.02 at the band edges. In the implementation described, a high-thermal-conductivity metallic substrate is textured with a pyramidal tiling and subsequently coated with a thin lossy dielectric coating that enables high absorption and thermal uniformity across the target. The resulting target assembly is lightweight, has a low-geometric profile, and has survived repeated thermal cycling from room temperature to approx.4 K. Basic design considerations, governing equations, and test data for realizing the structure described are provided. The optical properties of selected absorptive materials-Acktar Fractal Black, Aeroglaze Z306, and Stycast 2850 FT epoxy loaded with stainless steel powder-are characterized and presented
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201706020001240LZ | 355KB | download |