科技报告详细信息
Spent Fuel Transportation Cask Response to the Caldecott Tunnel Fire Scenario
Adkins, Harold E. ; Koeppel, Brian J. ; Cuta, Judith M.
关键词: spent nuclear fuel transportation cask;    tunnel fire accident;    thermal modeling;   
DOI  :  10.2172/1160204
RP-ID  :  NUREG/CR-6894 Rev1
RP-ID  :  PNNL-15346
PID  :  OSTI ID: 1160204
Others  :  Other: 401001020
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

On April 7, 1982, a tank truck and trailer carrying 8,800 gallons of gasoline was involved in an accident in the Caldecott tunnel on State Route 24 near Oakland, California. The tank trailer overturned and subsequently caught fire. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook analyses to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by truck. The Fire Dynamics Simulator (FDS) code developed by National Institute of Standards and Technology (NIST) was used to determine the thermal environment in the Caldecott tunnel during the fire. The FDS results were used to define boundary conditions for a thermal transient model of a truck transport cask containing spent nuclear fuel. The Nuclear Assurance Corporation (NAC) Legal Weight Truck (LWT) transportation cask was selected for this evaluation, as it represents a typical truck (over-the-road) cask, and can be used to transport a wide variety of spent nuclear fuels. Detailed analysis of the cask response to the fire was performed using the ANSYSÂŽ computer code to evaluate the thermal performance of the cask design in this fire scenario. This report describes the methods and approach used to assess the thermal response of the selected cask design to the conditions predicted in the Caldecott tunnel fire. The results of the analysis are presented in detail, with an evaluation of the cask response to the fire. The staff concluded that some components of smaller transportation casks resembling the NAC LWT, despite placement within an ISO container, could degrade significantly. Small transportation casks similar to the NAC LWT would probably experience failure of seals in this severe accident scenario. USNRC staff evaluated the radiological consequences of the cask response to the Caldecott tunnel fire. Although some components heated up beyond their service temperatures, the staff determined that there would be no significant release as a result of the fire for the NAC LWT and similar casks.

【 预 览 】
附件列表
Files Size Format View
RO201705190003103LZ 5610KB PDF download
  文献评价指标  
  下载次数:25次 浏览次数:15次