科技报告详细信息
JV Task 99-Integrated Risk Analysis and Contaminant Reduction, Watford City, North Dakota
Jaroslav Solc ; Barry W. Botnen
关键词: BRINES;    CONSTRUCTION;    ELECTRIC CONDUCTIVITY;    EVALUATION;    FLUORESCENCE;    LASERS;    RISK ASSESSMENT;    SOILS;    TANKS;   
DOI  :  10.2172/907879
RP-ID  :  None
PID  :  OSTI ID: 907879
Others  :  TRN: US200721%%554
学科分类:环境科学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Energy & Environmental Research Center (EERC) conducted a limited site investigation and risk analyses for hydrocarbon-contaminated soils and groundwater at a Construction Services, Inc., site in Watford City, North Dakota. Site investigation confirmed the presence of free product and high concentrations of residual gasoline-based contaminants in several wells, the presence of 1,2-dichloroethane, and extremely high levels of electrical conductivity indicative of brine residuals in the tank area south of the facility. The risk analysis was based on compilation of information from the site-specific geotechnical investigation, including multiphase extraction pilot test, laser induced fluorescence probing, evaluation of contaminant properties, receptor survey, capture zone analysis and evaluation of well head protection area for municipal well field. The project results indicate that the risks associated with contaminant occurrence at the Construction Services, Inc. site are low and, under current conditions, there is no direct or indirect exposure pathway between the contaminated groundwater and soils and potential receptors.

【 预 览 】
附件列表
Files Size Format View
RO201705190001809LZ 26808KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:36次