Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation
Zaltash, Abdolreza1 
[1] ORNL
关键词: AIR CONDITIONING;    AMBIENT TEMPERATURE;    EVALUATION;    FIELD TESTS;    MANUFACTURERS;    ORNL;    OUTDOORS;    PERFORMANCE;    REFRIGERANTS;    SITE SELECTION;    TESTING;    VELOCITY;   
DOI  :  10.2172/993004
RP-ID  :  ORNL/TM-2007/174
PID  :  OSTI ID: 993004
Others  :  Other: 400403309
Others  :  TRN: US201023%%400
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, and Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.

【 预 览 】
附件列表
Files Size Format View
RO201705190001084LZ 3494KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:24次