科技报告详细信息
ELECTROCHEMICAL CORROSION TESTS FOR TANK 241-AY-101 CORE 325 SEGMENTS 16R1 & 16R2
DUNCAN JB ; WYRWAS RB
关键词: CARBON STEELS;    CHEMISTRY;    CORROSION;    CURRENT DENSITY;    ELECTROCHEMICAL CORROSION;    HYDROXIDES;    HYSTERESIS;    INTERSTITIALS;    MITIGATION;    POLARIZATION;    SAFETY;    SPECIFICATIONS;    STORAGE FACILITIES;    TANKS;   
DOI  :  10.2172/940019
RP-ID  :  RPP-RPT-35554 Rev 1
PID  :  OSTI ID: 940019
Others  :  TRN: US200823%%755
学科分类:材料科学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The interstitial liquid in the double-shell tank 241-AY-101 settled solids layer is below the hydroxide chemistry control limit required by HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control 5.16, 'Corrosion Mitigation Controls'. Operating tanks outside of the specification may increase the propensity corrosion of the carbon steel wall. This report is concerned with generalized electrochemical corrosion mechanism that may occur at specific loci. All cyclic potentiodynamic polarization scans exhibited a negative hysteresis, scan reversing at lower current density, indicating that there was no pitting propensity. The general electrochemical corrosion rates ranged from 4.4E-02 to 1.5E-03 mpy with the first round of coupons, while the second round yielded corrosion rates of 2.5E-03 to 2.9E-02 mpy.