Performance Testing and Validation Plan for HMS4 Quantitative Gamma Measurements, K-25/K-27 D&D Project, East Tennessee Technology Park, Oak Ridge, Tennessee | |
Thiesing, J. W. ; Donohoue, Tom ; McCague, Jim ; Martin, Ray ; Royce, Ralph ; Thomas, Troy | |
关键词: ALGORITHMS; ATTENUATION; BACKGROUND RADIATION; CALIBRATION; CORRECTIONS; DETECTION; EFFICIENCY; OAK RIDGE; PERFORMANCE TESTING; COMPUTERIZED SIMULATION; SODIUM IODIDES; SPECTROMETERS; TENNESSEE; THALLIUM; URANIUM ISOTOPES; URANIUM 235; VALIDATION P; HMS4; Quantitative Gamma Measurements; K-25/K-27 D&D; | |
DOI : 10.2172/949979 RP-ID : BJC/OR-2930/R1 PID : OSTI ID: 949979 Others : TRN: US201002%%1452 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
The Holdup Measurement System 4 (HMS4) is a portable thallium activated sodium iodide (NaI[Tl]) gamma ray energy spectrometer that, when properly calibrated, is able to make quantifiable assessment of U-235 holdup in the presence of other uranium isotopes and prevailing background radiation. The use and calibration of the HMS4 is based upon the methodologies defined by Russo in La-14206, (Russo 2005), where detection efficiency determination protocols are defined (called Generalized Geometry Holdup [GGH]). The GGH methodology together with attenuation correction algorithms and other modeling parameters are combined in the HMS4 software package to provide a comprehensive tool for conducting in situ gamma-ray measurements. The fundamental principles of these capabilities are discussed.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201705180002142LZ | 2496KB | download |