A highly contaminated glove-box at LLNL containing plutonium was decontaminated using a strippable decontamination gel. 6 x 12 inch quadrants were mapped out on each of the surfaces. The gel was applied to various surfaces inside the glove-box and was allowed to cure. The radioactivity in each quadrant was measured using a LLNL Blue Alpha meter with a 1.5 inch standoff distance. The results showed decontamination factors of 130 and 210 on cast steel and Lexan{reg_sign} surfaces respectively after several applications. The gel also absorbed more than 91% of the radiation emitted from the surfaces during gel curing. The removed strippable film was analyzed by neutron multiplicity counting and gamma spectroscopy, yielding relative mass information and radioisotopic composition respectively.