科技报告详细信息
TANK 241-AN-102 MULTI-PROBE CORROSION MONITORING SYSTEM PROJECT LESSONS LEARNED
TAYLOR T ; HAGENSEN A ; KIRCH NW
关键词: AR FACILITIES;    STORAGE FACILITIES;    RADIOACTIVE WASTE STORAGE;    MONITORS;    CORROSION;    DESIGN;    ELECTRIC CONDUCTIVITY;    MONITORING;    FABRICATION;    TESTING;    STEELS;   
DOI  :  10.2172/934868
RP-ID  :  RPP-RPT-37508 Rev 0
PID  :  OSTI ID: 934868
Others  :  TRN: US0804111
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

During 2007 and 2008, a new Multi-Probe Corrosion Monitoring System (MPCMS) was designed and fabricated for use in double-shell tank 241-AN-102. The system was successfully installed in the tank on May 1, 2008. The 241-AN-102 MPCMS consists of one 'fixed' in-tank probe containing primary and secondary reference electrodes, tank material electrodes, Electrical Resistance (ER) sensors, and stressed and unstressed corrosion coupons. In addition to the fixed probe, the 241-AN-102 MPCMS also contains four standalone coupon racks, or 'removable' probes. Each rack contains stressed and unstressed coupons made of American Society of Testing and Materials A537 CL1 steel, heat-treated to closely match the chemical and mechanical characteristics of the 241-AN-102 tank wall. These coupon racks can be removed periodically to facilitate examination of the attached coupons for corrosion damage. Along the way to successful system deployment and operation, the system design, fabrication, and testing activities presented a number of challenges. This document discusses these challenges and lessons learned, which when applied to future efforts, should improve overall project efficiency.

【 预 览 】
附件列表
Files Size Format View
RO201705180001540LZ 4885KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:25次