科技报告详细信息
Recovery of Water from Boiler Flue Gas
Edward Levy ; Harun Bilirgen ; Kwangkook Jeong ; Michael Kessen ; Christopher Samuelson ; Christopher Whitcombe
关键词: FOSSIL-FUEL POWER PLANTS;    COAL;    VAPOR CONDENSERS;    DESIGN;    FLUE GAS;    HEAT EXCHANGERS;    WATER VAPOR;    MATERIALS RECOVERY;    WASTE HEAT;    HEAT RECOVERY;    FLOW MODELS;    HEAT TRANSFER;    MASS TRANSFER;    MERCURY;   
DOI  :  10.2172/952467
RP-ID  :  None
PID  :  OSTI ID: 952467
Others  :  TRN: US200913%%582
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature and low temperature regions of the heat transfer apparatus, while hydrochloric and nitric acid vapors condensed with the water vapor in the low temperature region. Measurements made of flue gas mercury concentrations upstream and downstream of the heat exchangers showed a significant reduction in flue gas mercury concentration within the heat exchangers. A theoretical heat and mass transfer model was developed for predicting rates of heat transfer and water vapor condensation and comparisons were made with pilot scale measurements. Analyses were also carried out to estimate how much flue gas moisture it would be practical to recover from boiler flue gas and the magnitude of the heat rate improvements which could be made by recovering sensible and latent heat from flue gas.

【 预 览 】
附件列表
Files Size Format View
RO201705180000892LZ 1780KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:19次