Polarimeters and Energy Spectrometers for the ILC Beam Delivery System
Boogert, S. ; /Royal Holloway, U. of London ; Hildreth, M. ; /Notre Dame U. ; Kafer, D. ; List, J. ; Monig, K. ; /DESY ; Moffeit, K.C. ; /SLAC ; Moortgat-Pick, G. ; /Durham U., IPPP ; Riemann, S. ; Schreiber, H.J. ; Schuler, P. ; /DESY ; Torrence, E. ; /Oregon U. ; Woods,
关键词: ACCELERATORS;    ACCURACY;    DESIGN;    EVALUATION;    PERFORMANCE;    POLARIMETERS;    POLARIZATION;    RECOMMENDATIONS;    REDUNDANCY;    SPECTROMETERS;    SPIN Accelerators;    Instrumentation;    ACCPHY;    HEPEX;    INST;   
DOI  :  10.2172/948484
RP-ID  :  SLAC-PUB-13551
PID  :  OSTI ID: 948484
Others  :  TRN: US0901756
学科分类:核物理和高能物理
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This article gives an overview of current plans and issues for polarimeters and energy spectrometers in the Beam Delivery System of the ILC. It is meant to serve as a useful reference for the Detector Letter of Intent documents currently being prepared. Concepts for high precision polarization and energy measurements exist. These concepts have resulted in detailed system layouts that are included in the RDR description for the Beam Delivery System. The RDR includes both upstream and downstream polarimeters and energy spectrometers for both beams. This provides needed complementarity and redundancy for achieving the precision required, with adequate control and demonstration of systematic errors. The BDS polarimeters and energy spectrometers need to be a joint effort of the ILC BDS team and the Detector collaborations, with collaboration members responsible for the performance and accuracy of the measurements. Details for this collaboration and assigning of responsibilities remain to be worked out. There is also a demonstrated need for Detector physicists to play an active role in the design and evaluation of accelerator components that impact beam polarization and beam energy capabilities, including the polarized source and spin rotator systems. A workshop was held in 2008 on ILC Polarization and Energy measurements, which resulted in a set of recommendations for the ILC design and operation. Additional input and action is needed on these from the Detector collaborations, the Research Director and the GDE. Work is continuing during the ILC engineering design phase to further optimize the polarimeter and energy spectrometer concepts and fully implement them in the ILC. This includes consideration for alternative methods, detailed design and cost estimates, and prototype and test beam activities.

【 预 览 】
附件列表
Files Size Format View
RO201705170002761LZ 326KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:16次