科技报告详细信息
Corrective Action Plan for Corrective Action Unit 563: Septic Systems, Nevada Test Site, Nevada
NSTec Environmental Restoration
关键词: ARSENIC;    CHROMIUM;    PIPELINES;    BACKFILLING;    GROUTING;    NEVADA TEST SITE;    SITE CHARACTERIZATION;    TANKS;    REMOVAL;    REMEDIAL ACTION Corrective Action Plan 563;    Nevada Test Site;   
DOI  :  10.2172/951602
RP-ID  :  DOE/NV--1313
PID  :  OSTI ID: 951602
Others  :  TRN: US1004019
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
This Corrective Action Plan (CAP) has been prepared for Corrective Action Unit (CAU) 563, Septic Systems, in accordance with the Federal Facility Agreement and Consent Order. CAU 563 consists of four Corrective Action Sites (CASs) located in Areas 3 and 12 of the Nevada Test Site. CAU 563 consists of the following CASs: CAS 03-04-02, Area 3 Subdock Septic Tank CAS 03-59-05, Area 3 Subdock Cesspool CAS 12-59-01, Drilling/Welding Shop Septic Tanks CAS 12-60-01, Drilling/Welding Shop Outfalls Site characterization activities were performed in 2007, and the results are presented in Appendix A of the CAU 563 Corrective Action Decision Document. The scope of work required to implement the recommended closure alternatives is summarized below. CAS 03-04-02, Area 3 Subdock Septic Tank, contains no contaminants of concern (COCs) above action levels. No further action is required for this site; however, as a best management practice (BMP), all aboveground features (e.g., riser pipes and bumper posts) will be removed, the septic tank will be removed, and all open pipe ends will be sealed with grout. CAS 03-59-05, Area 3 Subdock Cesspool, contains no COCs above action levels. No further action is required for this site; however, as a BMP, all aboveground features (e.g., riser pipes and bumper posts) will be removed, the cesspool will be abandoned by filling it with sand or native soil, and all open pipe ends will be sealed with grout. CAS 12-59-01, Drilling/Welding Shop Septic Tanks, will be clean closed by excavating approximately 4 cubic yards (yd3) of arsenic- and chromium-impacted soil. In addition, as a BMP, the liquid in the South Tank will be removed, the North Tank will be removed or filled with grout and left in place, the South Tank will be filled with grout and left in place, all open pipe ends will be sealed with grout or similar material, approximately 10 yd3 of chlordane-impacted soil will be excavated, and debris within the CAS boundary will be removed. CAS 12-60-01, Drilling/Welding Shop Outfalls, contains no COCs above action levels. No further action is required for this site; however, as a BMP, three drain pipe openings will be sealed with grout.
【 预 览 】
附件列表
Files Size Format View
RO201705170002395LZ 340KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:27次