科技报告详细信息
Low Probability Tail Event Analysis and Mitigation in BPA Control Area: Task One Report
Lu, Shuai ; Makarov, Yuri V.
关键词: CAPACITY;    DISTRIBUTION;    ELECTRIC RELIABILITY COUNCILS;    MITIGATION;    PLANNING;    POWER SYSTEMS;    PROBABILITY;    RELIABILITY power system;    tail events;    ancillary services;    load forecast;    wind forecast;   
DOI  :  10.2172/1034596
RP-ID  :  PNNL-19027
PID  :  OSTI ID: 1034596
Others  :  Other: 400480000
Others  :  TRN: US201204%%76
学科分类:电力
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
This is a report for task one of the tail event analysis project for BPA. Tail event refers to the situation in a power system when unfavorable forecast errors of load and wind are superposed onto fast load and wind ramps, or non-wind generators falling short of scheduled output, the imbalance between generation and load becomes very significant. This type of events occurs infrequently and appears on the tails of the distribution of system power imbalance; therefore, is referred to as tail events. This report analyzes what happened during the Electric Reliability Council of Texas (ERCOT) reliability event on February 26, 2008, which was widely reported because of the involvement of wind generation. The objective is to identify sources of the problem, solutions to it and potential improvements that can be made to the system. Lessons learned from the analysis include the following: (1) Large mismatch between generation and load can be caused by load forecast error, wind forecast error and generation scheduling control error on traditional generators, or a combination of all of the above; (2) The capability of system balancing resources should be evaluated both in capacity (MW) and in ramp rate (MW/min), and be procured accordingly to meet both requirements. The resources need to be able to cover a range corresponding to the variability of load and wind in the system, additional to other uncertainties; (3) Unexpected ramps caused by load and wind can both become the cause leading to serious issues; (4) A look-ahead tool evaluating system balancing requirement during real-time operations and comparing that with available system resources should be very helpful to system operators in predicting the forthcoming of similar events and planning ahead; and (5) Demand response (only load reduction in ERCOT event) can effectively reduce load-generation mismatch and terminate frequency deviation in an emergency situation.
【 预 览 】
附件列表
Files Size Format View
RO201705170002368LZ 162KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:51次