Closure Report for Corrective Action Unit 117: Area 26 Pluto Disassembly Facility, Nevada Test Site, Nevada, Revision 0 | |
Mark Burmeister | |
关键词: AIR FILTERS; BRICKS; CLOSURES; CONTAMINATION; DEMOLITION; ENVIRONMENTAL PROTECTION; NEVADA TEST SITE; PARTICULATES; POLYCHLORINATED BIPHENYLS; RADIUM 226; SAMPLING; SECURITY; SOILS; SWITCHES; THERMOSTATS; US DOD; WASTES; | |
DOI : 10.2172/963423 RP-ID : DOE/NV--1324 PID : OSTI ID: 963423 Others : TRN: US200918%%96 |
|
学科分类:环境科学(综合) | |
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 117: Area 26 Pluto Disassembly Facility, Nevada Test Site, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 117 comprises Corrective Action Site (CAS) 26-41-01, Pluto Disassembly Facility, located in Area 26 of the Nevada Test Site. The purpose of this CR is to provide documentation supporting the completed corrective actions and provide data confirming that the closure objectives for CAU 117 were met. To achieve this, the following actions were performed: ⢠Review the current site conditions, including the concentration and extent of contamination. ⢠Implement any corrective actions necessary to protect human health and the environment. ⢠Properly dispose of corrective action and investigation wastes. ⢠Document Notice of Completion and closure of CAU 117 issued by the Nevada Division of Environmental Protection. From May 2008 through February 2009, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 117, Area 26 Pluto Disassembly Facility, Nevada Test Site, Nevada. The purpose of the activities as defined during the data quality objectives process were: ⢠Determine whether contaminants of concern (COCs) are present. ⢠If COCs are present, determine their nature and extent, implement appropriate corrective actions, and properly dispose of wastes. Analytes detected during the closure activities were evaluated against final action levels to determine COCs for CAU 117. Assessment of the data generated from closure activities indicated that the final action levels were exceeded for polychlorinated biphenyls (PCBs) reported as total Aroclor and radium-226. A corrective action was implemented to remove approximately 50 cubic yards of PCB-contaminated soil, approximately 1 cubic foot of radium-226 contaminated soil (and scabbled asphalt), and a high-efficiency particulate air filter that was determined to meet the criteria of a potential source material (PSM). Electrical and lighting components (i.e., PCB-containing ballasts and capacitors) and other materials (e.g., mercury-containing thermostats and switches, lead plugs and bricks) assumed to be PSM were also removed from Building 2201, as practical, without the need for sampling. Because the COC contamination and PSMs have been removed, clean closure of CAS 26-41-01 is recommended, and no use restrictions are required to be placed on this CAU. No further action is necessary because no other contaminants of potential concern were found above preliminary action levels. The physical end state for Building 2201 is expected to be eventual demolition to slab. The DOE, National Nuclear Security Administration Nevada Site Office provides the following recommendations: ⢠Clean closure is the recommended corrective action for CAS 26-41-01 in CAU 117. ⢠A Notice of Completion to the DOE, National Nuclear Security Administration Nevada Site Office is requested from the Nevada Division of Environmental Protection for closure of CAU 117. ⢠Corrective Action Unit 117 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201705170001898LZ | 10725KB | download |