【 摘 要 】
The capability of EdotX would be improved by increasing the instrument's dynamic range to expand the range of signals measurable by the device. The heart of the EdotX system is a two channel analog to digital (A/D) conversion card with two analog to digital converters tightly coupled to a field programmable gate array (FPGA). Signals are continually digitized by the A/D and processed by the FPGA. When the FPGA detects a trigger condition, the data are transferred using direct memory access to the host computer memory, which in turn saves the data to disk. The original design utilizes a single A/D channel for data acquisition. The task was to increase the dynamic range of the system by enabling the second A/D channel, allowing the simultaneous acquisition of the original A/D channel and the additional second A/D channel. The input signal would be fed to the original channel and to the second channel with the second channel input being attenuated. When a signal hits the maximum range of the first channel, the data from the second channel, which is attenuated, are then used. Because both A/D's acquire data simultaneously, they may be used as a single expanded dynamic range channel.