科技报告详细信息
Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C
Gary Mecham ; Don Konoyer
关键词: BUILDINGS;    CALIBRATION;    CARBONATES;    CONTAMINATION;    ENVIRONMENT;    FILTERS;    FUELS;    HAZARDOUS MATERIALS;    HAZARDS;    HUMAN POPULATIONS;    INFORMATION;    JOINTS;    LEAKS;    MATERIALS;    NUCLEAR ENERGY;    REMOVAL;    SOUND WAVES;    SPECTROSCOPY;    STORAGE;    TANKS facility;   
DOI  :  10.2172/1001995
RP-ID  :  INL/EXT-09-17292
PID  :  OSTI ID: 1001995
Others  :  TRN: US201104%%126
学科分类:社会科学、人文和艺术(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document conditions at time of transfer of the facilities from Nuclear Energy to Environmental Management and serve as the basis for disposition planning. The process used in obtaining this information included document searches, interviews and facility walk-downs. A copy of the facility walk-down checklist is included in this report as Appendix A. MFC-799/799A/770C are all structurally sound and associated hazardous or potentially hazardous conditions are well defined and well understood. All installed equipment items (tanks, filters, etc.) used to process hazardous materials remain in place and appear to have maintained their integrity. There is no evidence of leakage and all openings are properly sealed or closed off and connections are sound. The pits appear clean with no evidence of cracking or deterioration that could lead to migration of contamination. Based upon the available information/documentation reviewed and the overall conditions observed during the facilities walk-down, it is concluded that these facilities may be disposed of at minimal risk to human health, safety or the environment.

【 预 览 】
附件列表
Files Size Format View
RO201705170000491LZ 17148KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:26次