AN EXPERIMENTAL STUDY OF THE STABILITY OF VESSEL-SPANNING BUBBLES IN CYLINDRICAL & ANNULAR & OBROUND & AND CONICAL CONTAINERS | |
DHALIWAL TK | |
关键词: AR FACILITIES; BUBBLES; CONTAINERS; DESIGN; HYDRAULICS; MATERIAL BALANCE; PLUGGING; SHEAR PROPERTIES; SLUDGES; STABILITY; STORAGE; TANKS; TRANSPORT; WASTE STORAGE; WIPP; | |
DOI : 10.2172/978602 RP-ID : PRC-STP-00177 Rev 0 PID : OSTI ID: 978602 Others : Other: PRC-STP-10-44543 Others : TRN: US1003133 |
|
学科分类:核能源与工程 | |
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
This report provides a summary of experiments that were performed by Fauske & Associates on the stability of vessel-spanning bubbles. The report by Fauske & Associates, An Experimental Study of the Stability of Vessel-Spanning Bubbles in Cylindrical, Annular, Obround and Conical Containers, is included in Appendix A. Results from the experiments confirm that the gravity yield parameter, Y{sub G}, correctly includes container size and can be applied to full-scale containers to predict the possibility of the formation of a stable vessel spanning bubble. The results also indicate that a vessel spanning bubble will likely form inside the STSC for KE, KW, and Settler sludges if the shear strengths of these sludges exceed 1820, 2080, and 2120 Pa, respectively. A passive mechanism installed in the STSC is effective at disrupting a rising sludge plug and preventing the sludge from plugging the vent filter or being forced out of the container. The Sludge Treatment Project for Engineered Container and Settler Sludge (EC/ST) Disposition Subproject is being conducted in two phases. Phase 1 of the EC/ST Disposition Subproject will retrieve the radioactive sludge currently stored in the K West (KW) Basin into Sludge Transport and Storage Containers (STSCs) and transport the STSCs to T-Plant for interim storage. Phase 2 of the EC/ST Disposition Subproject will retrieve the sludge from interim storage, treat and package sludge for disposal at the Waste Isolation Pilot Plant. The STSC is a cylindrical container; similar to previously used large diameter containers. A STSC (Figure 1) with a diameter of 58 inches will be used to transport KE and KW originating sludge (located in Engineered Containers 210, 220, 240, 250, and 260) to T-Plant. A STSC with an annulus (Figure 2) will be used to transport Settler Tank sludge, located in Engineered Container 230. An obround small canister design was previously considered to retrieve sludge from the basin. The obround design was selected in Small Canister Design Selection, PRC-STP-00052. However, the small canister was not selected for transporting the sludge. The STSC was selected for sludge loading and transport to T-Plant as discussed in Decision Report for Direct Hydraulic Loading of Sludge into Sludge Transport and Storage Containers, PRC-STP-00112. The STSC will be directly loaded with sludge as described in the Preliminary STP Container and Settler Sludge Process System Description and Material Balance, HNF-41051.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704240003161LZ | 10057KB | download |