科技报告详细信息
Dynamic load test of Arquin-designed CMU wall.
Jensen, Richard Pearson
关键词: BUSINESS;    CONCRETE BLOCKS;    DYNAMIC LOADS;    EXPLOSIVES;    PERFORMANCE;    POLYMERS;    SANDIA NATIONAL LABORATORIES;    SPACERS;    STEELS Concrete-Fracture.;    Reinforced concrete-Testing.;    Concrete-Testing.;   
DOI  :  10.2172/978431
RP-ID  :  SAND2010-1181
PID  :  OSTI ID: 978431
Others  :  TRN: US201010%%489
学科分类:材料科学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Arquin Corporation has developed a new method of constructing CMU (concrete masonry unit) walls. This new method uses polymer spacers connected to steel wires that serve as reinforcing as well as a means of accurately placing the spacers so that the concrete block can be dry stacked. The hollows of the concrete block are then filled with grout. As part of a New Mexico Small Business Assistance Program (NMSBA), Sandia National Laboratories conducted a series of tests that dynamically loaded wall segments to compare the performance of walls constructed using the Arquin method to a more traditional method of constructing CMU walls. A total of four walls were built, two with traditional methods and two with the Arquin method. Two of the walls, one traditional and one Arquin, had every third cell filled with grout. The remaining two walls, one traditional and one Arquin, had every cell filled with grout. The walls were dynamically loaded with explosive forces. No significant difference was noted between the performance of the walls constructed by the Arquin method when compared to the walls constructed by the traditional method.

【 预 览 】
附件列表
Files Size Format View
RO201704240003087LZ 1706KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:5次