科技报告详细信息
Selected test results from the neosonic polymer Li-ion battery.
Ingersoll, David T. ; Hund, Thomas D.
关键词: CAPACITY;    CONFINEMENT;    ELECTRIC CONDUCTIVITY;    GASES;    IMPEDANCE;    PERFORMANCE;    POLYMERS;    SAFETY;    WIND TURBINE ARRAYS Storage batteries.;    Lithium cells.;    Storage batteries-Testing.;   
DOI  :  10.2172/989349
RP-ID  :  SAND2010-4862
PID  :  OSTI ID: 989349
Others  :  TRN: US201019%%605
学科分类:再生能源与代替技术
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The performance of the Neosonic polymer Li-ion battery was measured using a number of tests including capacity, capacity as a function of temperature, ohmic resistance, spectral impedance, hybrid pulsed power test, utility partial state of charge (PSOC) pulsed cycle test, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the polymer Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, wind farm energy smoothing, and solar photovoltaic energy smoothing. Test results have indicated that the Neosonic polymer Li-ion battery technology can provide power levels up to the 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h (1C) discharge rate. Two of the three cells used in the utility PSOC pulsed cycle test completed about 12,000 cycles with only a gradual loss in capacity of 10 and 13%. The third cell experienced a 40% loss in capacity at about 11,000 cycles. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were increases in impedance after cycling, especially for the third cell. Cell No.3 impedance Rs increased significantly along with extensive ballooning of the foil pouch. Finally, at a 1C (10 A) charge rate, the over charge/voltage abuse test with cell confinement similar to a multi cell string resulted in the cell venting hot gases at about 45 C 45 minutes into the test. At 104 minutes into the test the cell voltage spiked to the 12 volt limit and continued out to the end of the test at 151 minutes. In summary, the Neosonic cells performed as expected with good cycle-life and safety.

【 预 览 】
附件列表
Files Size Format View
RO201704240001806LZ 825KB PDF download
  文献评价指标  
  下载次数:22次 浏览次数:79次