科技报告详细信息
Conceptual Design of Forced Convection Molten Salt Heat Transfer Testing Loop
Manohar S. Sohal ; Piyush Sabharwall ; Pattrick Calderoni ; Alan K. Wertsching ; S. Brandon Grover
关键词: CONSTRUCTION;    COOLANTS;    CORROSION;    DATA ACQUISITION SYSTEMS;    DESIGN;    FORCED CONVECTION;    HEAT EXCHANGERS;    HEAT TRANSFER;    IMPURITIES;    MEASURING INSTRUMENTS;    MOLTEN SALTS;    PROBABILITY;    PRODUCTION;    PURIFICATION;    SAFETY;   
DOI  :  10.2172/1000546
RP-ID  :  INL/EXT-10-19908
PID  :  OSTI ID: 1000546
Others  :  TRN: US1100220
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report develops a proposal to design and construct a forced convection test loop. A detailed test plan will then be conducted to obtain data on heat transfer, thermodynamic, and corrosion characteristics of the molten salts and fluid-solid interaction. In particular, this report outlines an experimental research and development test plan. The most important initial requirement for heat transfer test of molten salt systems is the establishment of reference coolant materials to use in the experiments. An earlier report produced within the same project highlighted how thermophysical properties of the materials that directly impact the heat transfer behavior are strongly correlated to the composition and impurities concentration of the melt. It is therefore essential to establish laboratory techniques that can measure the melt composition, and to develop purification methods that would allow the production of large quantities of coolant with the desired purity. A companion report describes the options available to reach such objectives. In particular, that report outlines an experimental research and development test plan that would include following steps: ???Molten Salts: The candidate molten salts for investigation will be selected. ???Materials of Construction: Materials of construction for the test loop, heat exchangers, and fluid-solid corrosion tests in the test loop will also be selected. ???Scaling Analysis: Scaling analysis to design the test loop will be performed. ???Test Plan: A comprehensive test plan to include all the tests that are being planned in the short and long term time frame will be developed. ???Design the Test Loop: The forced convection test loop will be designed including extensive mechanical design, instrument selection, data acquisition system, safety requirements, and related precautionary measures. ???Fabricate the Test Loop. ???Perform the Tests. ???Uncertainty Analysis: As a part of the data collection, uncertainty analysis will be performed to develop probability of confidence in what is measured in the test loop. Overall, the testing loop will allow development of needed heat transfer related thermophysical parameters for all the salts, validate existing correlations, validate measuring instruments under harsh environment, and have extensive corrosion testing of materials of construction.

【 预 览 】
附件列表
Files Size Format View
RO201704240001171LZ 3176KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:20次