Uranium Adsorption on Ion-Exchange Resins - Batch Testing | |
Mattigod, Shas V. ; Golovich, Elizabeth C. ; Wellman, Dawn M. ; Cordova, Elsa A. ; Smith, Ronald M. | |
关键词: ADSORPTION; ADSORPTION ISOTHERMS; ORGANIC ION EXCHANGERS; PERFORMANCE; RESINS; MATERIALS TESTING; URANIUM; GROUND WATER; REMEDIAL ACTION; SERVICE LIFE; | |
DOI : 10.2172/1009765 RP-ID : PNNL-20135 PID : OSTI ID: 1009765 Others : Other: 830403000 Others : TRN: US1101909 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
The uranium adsorption performance of five resins (Dowex 1, Dowex 21K 16-30 [fresh], Dowex 21K 16-30 [regenerated], Purofine PFA600/4740, and ResinTech SIR-1200) were tested using unspiked, nitrate-spiked, and nitrate-spiked/pH adjusted source water from well 299-W19-36. These batch tests were conducted in support of a resin selection process in which the best resin to use for uranium treatment in the 200-West Area groundwater pump-and-treat system will be identified. The results from these tests are as follows: ??? The data from the high-nitrate (1331 mg/L) tests indicated that Dowex 1, Dowex 21K 16-30 (fresh), Purofine PFA600/4740, and ResinTech SIR-1200 all adsorbed uranium similarly well with Kd values ranging from ~15,000 to 95,000 ml/g. All four resins would be considered suitable for use in the treatment system based on uranium adsorption characteristics. ??? Lowering the pH of the high nitrate test conditions from 8.2 to 7.5 did not significantly change the uranium adsorption isotherms for the four tested resins. The Kd values for these four resins under high nitrate (1338 mg/L), lower pH (7.5) ranged from ~15,000 to 80,000 ml/g. ??? Higher nitrate concentrations greatly reduced the uranium adsorption on all four resins. Tests conducted with unspiked (no amendments; nitrate at 337 mg/L and pH at 8.2) source water yielded Kd values for Dowex 1, Dowex 21K 16-30 (fresh), Purofine PFA600/4740, and ResinTech SIR-1200 resins ranging from ~800,000 to >3,000,000 ml/g. These values are about two orders of magnitude higher than the Kd values noted from tests conducted using amended source water. ??? Compared to the fresh resin, the regenerated Dowex 21K 16-30 resin exhibited significantly lower uranium-adsorption performance under all test conditions. The calculated Kd values for the regenerated resin were typically an order of magnitude lower than the values calculated for the fresh resin. ??? Additional testing using laboratory columns is recommended to better resolve differences between the adsorption abilities of the resins and to develop estimates of uranium loading on the resins. By determining the quantity of uranium that each resin can adsorb and the time required to reach various levels of loading, resin lifetime in the treatment system can be estimated.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704240000310LZ | 968KB | download |