SCALING SOLID RESUSPENSION AND SORPTION FOR THE SMALL COLUMN ION EXCHANGE PROCESSING TANK
Poirier, M. ; Qureshi, Z.
关键词: AR FACILITIES;    ACTINIDES;    CESIUM;    DIMENSIONS;    ION EXCHANGE;    LIQUID WASTES;    MASS TRANSFER;    NOZZLES;    PARTICLE RESUSPENSION;    PROCESSING;    SAVANNAH RIVER PLANT;    SCALE MODELS;    SORPTION;    S;   
DOI  :  10.2172/1041516
RP-ID  :  SRNL-STI-2010-00792
PID  :  OSTI ID: 1041516
Others  :  TRN: US1202830
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing 1.3 million gallon waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending and resuspending Monosodium Titanate (MST), Crystalline Silicotitanate (CST), and simulated sludge. In addition, SRNL will also be conducting pilot-scale tests to determine the mixing requirements for the strontium and actinide sorption. As part of this task, the results from the pilot-scale tests must be scaled up to a full-scale waste tank. This document describes the scaling approach. The pilot-scale tank is a 1/10.85 linear scale model of Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX Program (Risers B5 and B2 for two pump configurations and Risers B5, B3, and B1 for three pump configurations). MST additions are through Riser E1, the proposed MST addition riser in Tank 41H. To determine the approach to scaling the results from the pilot-scale tank to Tank 41H, the authors took the following approach. They reviewed the technical literature for methods to scale mixing with jets and suspension of solid particles with jets, and the technical literature on mass transfer from a liquid to a solid particle to develop approaches to scaling the test data. SRNL assembled a team of internal experts to review the scaling approach and to identify alternative approaches that should be considered.
【 预 览 】
附件列表
Files Size Format View
RO201704240000144LZ 617KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:36次