| Multiple error data analysis for RHIC low-energy operations | |
| Montag, C. | |
| 关键词: BETATRONS; DATA ANALYSIS; GOLD; LIFETIME; MAGNETS; MULTIPOLES; PERFORMANCE; SPACE CHARGE relativistic heavy ion collider; | |
| DOI : 10.2172/1007886 RP-ID : BNL--94627-2011-IR PID : OSTI ID: 1007886 Others : R&D Project: KBCH139 Others : 18031 Others : Other: KB0202011 Others : TRN: US1101796 |
|
| 学科分类:核物理和高能物理 | |
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
In FY10, RHIC operated with gold beams at three different energies below its regular injection energy, namely at {radical}s = 5 GeV; 7.7 GeV; and 11.5 GeV: While beam lifetimes of about 10 minutes were achieved at 11.5 GeV and 7.7 GeV; leading to stable collider operation, beam lifetimes during tests at {radical}s = 5 GeV were only of the order of several seconds. Though space charge effects are a major concern in low energy operations due to the 1/{gamma}{sup 2} scaling of the space charge force, these can effectively be ruled out as the main cause of this abysmal performance because of the tiny bunch intensities of approximately 10{sub 8} Au/bunch, compared to 10{sup 9} Au/bunch at the two higher energies. During these 5 GeV tests, large betatron tune spreads were observed, but the extremely short beam lifetime prevented chromaticity measurements. Instead, chromaticities were scanned over a range of 40 units, but to no effect. It was therefore suspected at that time that the large tune spread was caused by higherorder multipole errors in the RHIC magnets.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201704210003428LZ | 560KB |
PDF