科技报告详细信息
Multiple error data analysis for RHIC low-energy operations
Montag, C.
关键词: BETATRONS;    DATA ANALYSIS;    GOLD;    LIFETIME;    MAGNETS;    MULTIPOLES;    PERFORMANCE;    SPACE CHARGE relativistic heavy ion collider;   
DOI  :  10.2172/1007886
RP-ID  :  BNL--94627-2011-IR
PID  :  OSTI ID: 1007886
Others  :  R&D Project: KBCH139
Others  :  18031
Others  :  Other: KB0202011
Others  :  TRN: US1101796
学科分类:核物理和高能物理
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

In FY10, RHIC operated with gold beams at three different energies below its regular injection energy, namely at {radical}s = 5 GeV; 7.7 GeV; and 11.5 GeV: While beam lifetimes of about 10 minutes were achieved at 11.5 GeV and 7.7 GeV; leading to stable collider operation, beam lifetimes during tests at {radical}s = 5 GeV were only of the order of several seconds. Though space charge effects are a major concern in low energy operations due to the 1/{gamma}{sup 2} scaling of the space charge force, these can effectively be ruled out as the main cause of this abysmal performance because of the tiny bunch intensities of approximately 10{sub 8} Au/bunch, compared to 10{sup 9} Au/bunch at the two higher energies. During these 5 GeV tests, large betatron tune spreads were observed, but the extremely short beam lifetime prevented chromaticity measurements. Instead, chromaticities were scanned over a range of 40 units, but to no effect. It was therefore suspected at that time that the large tune spread was caused by higherorder multipole errors in the RHIC magnets.

【 预 览 】
附件列表
Files Size Format View
RO201704210003428LZ 560KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:27次