科技报告详细信息
National Ignition Campaign (NIC) Precision Tuning Series Shock Timing Experiments
Robey, H F ; Celliers, P M
关键词: ACCURACY;    CONES;    DEUTERIUM;    IGNITION;    INTERFEROMETERS;    LASERS;    SHAPE;    SHOCK WAVES;    TUNING;    VELOCITY;   
DOI  :  10.2172/1022942
RP-ID  :  LLNL-TR-492212
PID  :  OSTI ID: 1022942
Others  :  TRN: US1104493
学科分类:原子、分子光学和等离子物理
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
A series of precision shock timing experiments have been performed on NIF. These experiments continue to adjust the laser pulse shape and employ the adjusted cone fraction (CF) in the picket (1st 2 ns of the laser pulse) as determined from the re-emit experiment series. The NIF ignition laser pulse is precisely shaped and consists of a series of four impulses, which drive a corresponding series of shock waves of increasing strength to accelerate and compress the capsule ablator and fuel layer. To optimize the implosion, they tune not only the strength (or power) but also, to sub-nanosecond accuracy, the timing of the shock waves. In a well-tuned implosion, the shock waves work together to compress and heat the fuel. For the shock timing experiments, a re-entrant cone is inserted through both the hohlraum wall and the capsule ablator allowing a direct optical view of the propagating shocks in the capsule interior using the VISAR (Velocity Interferometer System for Any Reflector) diagnostic from outside the hohlraum. To emulate the DT ice of an ignition capsule, the inside of the cone and the capsule are filled with liquid deuterium.
【 预 览 】
附件列表
Files Size Format View
RO201704210001723LZ 2021KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:14次