Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report | |
Tim Roney ; Robert Seifert ; Bob Pink ; Mike Smith | |
关键词: COMPUTERIZED TOMOGRAPHY; DETECTION; MANUFACTURERS; MILITARY EQUIPMENT; VIABILITY chemical munitions; imaging; Radiography; x-ray; x-ray detection; | |
DOI : 10.2172/1035898 RP-ID : INL/EXT-11-23455 PID : OSTI ID: 1035898 Others : TRN: US201205%%475 |
|
学科分类:工程和技术(综合) | |
美国|英语 | |
来源: SciTech Connect | |
![]() |
【 摘 要 】
The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integration into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704210001321LZ | 1256KB | ![]() |