科技报告详细信息
Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report
Tim Roney ; Robert Seifert ; Bob Pink ; Mike Smith
关键词: COMPUTERIZED TOMOGRAPHY;    DETECTION;    MANUFACTURERS;    MILITARY EQUIPMENT;    VIABILITY chemical munitions;    imaging;    Radiography;    x-ray;    x-ray detection;   
DOI  :  10.2172/1035898
RP-ID  :  INL/EXT-11-23455
PID  :  OSTI ID: 1035898
Others  :  TRN: US201205%%475
学科分类:工程和技术(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integration into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.

【 预 览 】
附件列表
Files Size Format View
RO201704210001321LZ 1256KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:83次