科技报告详细信息
MCNP5 CALCULATIONS REPLICATING ARH-600 NITRATE DATA
FINFROCK SH
关键词: AUTOMATION;    CRITICALITY;    CROSS SECTIONS;    DIMENSIONS;    NITRATES;    PERSONNEL;    PLUTONIUM NITRATES;    SAFETY MARGINS;    THICKNESS;    URANYL NITRATES;   
DOI  :  10.2172/1047869
RP-ID  :  CHPRC-01552 Rev 0
PID  :  OSTI ID: 1047869
Others  :  TRN: US201216%%721
学科分类:社会科学、人文和艺术(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
This report serves to extend the previous document: 'MCNP Calculations Replicating ARH-600 Data' by replicating the nitrate curves found in ARH-600. This report includes the MCNP models used, the calculated critical dimension for each analyzed parameter set, and the resulting data libraries for use with the CritView code. As with the ARH-600 data, this report is not meant to replace the analysis of the fissile systems by qualified criticality personnel. The M CNP data is presented without accounting for the statistical uncertainty (although this is typically less than 0.001) or bias and, as such, the application of a reasonable safety margin is required. The data that follows pertains to the uranyl nitrate and plutonium nitrate spheres, infinite cylinders, and infinite slabs of varying isotopic composition, reflector thickness, and molarity. Each of the cases was modeled in MCNP (version 5.1.40), using the ENDF/B-VI cross section set. Given a molarity, isotopic composition, and reflector thickness, the fissile concentration and diameter (or thicknesses in the case of the slab geometries) were varied. The diameter for which k-effective equals 1.00 for a given concentration could then be calculated and graphed. These graphs are included in this report. The pages that follow describe the regions modeled, formulas for calculating the various parameters, a list of cross-sections used in the calculations, a description of the automation routine and data, and finally the data output. The data of most interest are the critical dimensions of the various systems analyzed. This is presented graphically, and in table format, in Appendix B. Appendix C provides a text listing of the same data in a format that is compatible with the CritView code. Appendices D and E provide listing of example Template files and MCNP input files (these are discussed further in Section 4). Appendix F is a complete listing of all of the output data (i.e., all of the analyzed dimensions and the resulting k{sub eff} values).
【 预 览 】
附件列表
Files Size Format View
RO201704210000620LZ 27958KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:7次