Standard Hydrogen Test Protocols for the NREL Sensor Testing Laboratory (Brochure)
关键词: EVALUATION;    FLUCTUATIONS;    HUMIDITY;    HYDROGEN;    MANUFACTURERS;    MONITORS;    OXYGEN;    PERFORMANCE;    SAFETY;    SENSORS;    SPECIFICATIONS;    STABILITY;    TESTING STANDARD TEST PROTOCOLS;    NREL HYDROGEN SENSOR TEST LABORATORY;    ISO STANDARD 26142;    Hydrogen Technologies and Systems;   
DOI  :  10.2172/1032663
RP-ID  :  NREL/BR-5600-53079
PID  :  OSTI ID: 1032663
Others  :  TRN: US201202%%394
学科分类:再生能源与代替技术
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This brochure summarizes the test protocols used in the NREL Hydrogen Sensor Test Laboratory for the quantitative assessment of critical analytical performance specifications for hydrogen sensors. Researchers at the NREL Hydrogen Safety Sensor Test Laboratory developed a variety of test protocols to quantitatively assess critical analytical performance specifications for hydrogen sensors. Many are similar to, but typically more rigorous than, the test procedures mandated by ISO Standard 26142 (Hydrogen Detector for Stationary Applications). Specific protocols were developed for linear range, short-term stability, and the impact of fluctuations in temperature (T), pressure (P), relative humidity (RH), and chemical environment. Specialized tests (e.g., oxygen requirement) may also be performed. Hydrogen safety sensors selected for evaluation are subjected to a thorough regimen of test protocols, as described. Sensor testing is performed at NREL on custom-built sensor test fixtures. Environmental parameters such as T, P, RH, and gas composition are rigorously controlled and monitored. The NREL evaluations are performed on commercial hydrogen detectors, on emerging sensing technologies, and for end users to validate sensor performance for specific application needs. Test results and data are shared with the manufacturer or client via summary reports, teleconference phone calls, and, when appropriate, site visits to manufacturer facilities. Client representatives may also monitor NREL's operation while their technologies are being tested. Manufacturers may use test data to illustrate the analytical capability of their technologies and, more importantly, to guide future developments. NREL uses the data to assess technology gaps and deployment considerations. Per NREL Sensor Testing Laboratory policy, test results are treated as proprietary and are not shared with other manufacturers or other entities without permission. The data may be used by NREL in open publications (journal articles, presentations, outreach support, and other reports), but will not be attributed to a specific vendor.

【 预 览 】
附件列表
Files Size Format View
RO201704210000201LZ 734KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:15次