科技报告详细信息
Criticality Safety Controls for 55-Gallon Drums with a Mass Limit of 200 grams Pu-239
Chou, P
关键词: AR FACILITIES;    BERYLLIUM;    CARBON;    CONTAINERS;    CRITICALITY;    GRAPHITE;    HYDROGEN;    PARAFFIN;    PLUTONIUM;    PLUTONIUM 239;    POLYETHYLENES;    REFLECTION;    SAFETY;    STEELS;    STORAGE;    URANIUM 235;    WASTES;   
DOI  :  10.2172/1034515
RP-ID  :  LLNL-TR-521191
PID  :  OSTI ID: 1034515
Others  :  TRN: US1200875
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The following 200-gram Pu drum criticality safety controls are applicable to RHWM drum storage operations: (1) Mass (Fissile/Pu) - each 55-gallon drum or its equivalent shall be limited to 200 gram Pu or Pu equivalent; (2) Moderation - Hydrogen materials with a hydrogen density greater than that (0.133 g H/cc) of polyethylene and paraffin are not allowed and hydrogen materials with a hydrogen density no greater than that of polyethylene and paraffin are allowed with unlimited amounts; (3) Interaction - a spacing of 30-inches (76 cm) is required between arrays and 200-gram Pu drums shall be placed in arrays for 200-gram Pu drums only (no mingling of 200-gram Pu drums with other drums not meeting the drum controls associated with the 200-gram limit); (4) Reflection - no beryllium and carbon/graphite (other than the 50-gram waiver amount) is allowed, (note that Nat-U exceeding the waiver amount is allowed when its U-235 content is included in the fissile mass limit of 200 grams); and (5) Geometry - drum geometry, only 55-gallon drum or its equivalent shall be used and array geometry, 55-gallon drums are allowed for 2-high stacking. Steel waste boxes may be stacked 3-high if constraint.

【 预 览 】
附件列表
Files Size Format View
RO201704210000134LZ 274KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:33次