HTGR Application Economic Model Users' Manual | |
A.M. Gandrik | |
关键词: DEMONSTRATION PLANTS; DESIGN; ECONOMICS; GAS COOLED REACTORS; IDAHO NATIONAL LABORATORY; MARKET; MATHEMATICAL MODELS; MODIFICATIONS; PRICES; RANKINE CYCLE High Temperature Gas Reactor; Next Generation Nuclear Plant Project; NGNP; | |
DOI : 10.2172/1034805 RP-ID : INL/EXT-11-24143 PID : OSTI ID: 1034805 Others : TRN: US1200945 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
The High Temperature Gas-Cooled Reactor (HTGR) Application Economic Model was developed at the Idaho National Laboratory for the Next Generation Nuclear Plant Project. The HTGR Application Economic Model calculates either the required selling price of power and/or heat for a given internal rate of return (IRR) or the IRR for power and/or heat being sold at the market price. The user can generate these economic results for a range of reactor outlet temperatures; with and without power cycles, including either a Brayton or Rankine cycle; for the demonstration plant, first of a kind, or nth of a kind project phases; for up to 16 reactor modules; and for module ratings of 200, 350, or 600 MWt. This users manual contains the mathematical models and operating instructions for the HTGR Application Economic Model. Instructions, screenshots, and examples are provided to guide the user through the HTGR Application Economic Model. This model was designed for users who are familiar with the HTGR design and Excel and engineering economics. Modification of the HTGR Application Economic Model should only be performed by users familiar with the HTGR and its applications, Excel, and Visual Basic.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190004480LZ | 6277KB | download |