科技报告详细信息
Strategy Guideline. HVAC Equipment Sizing | |
Burdick, Arlan1  | |
[1] IBACOS, Inc., Pittsburgh, PA (United States) | |
关键词: IBACOS; heating ventilation and air-conditioning (HVAC) system; right sized; whole house energy use; equipment selection; air distribution; | |
DOI : 10.2172/1219527 RP-ID : DOE/GO--102012-3442 PID : OSTI ID: 1219527 Others : Other: 5553 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, FL. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190004287LZ | 4746KB | download |