ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM - 2011 | |
West, B. ; Waltz, R. | |
关键词: AR FACILITIES; CARBON STEELS; CONFINEMENT; IMAGES; IN-SERVICE INSPECTION; RADIOACTIVE WASTES; SAVANNAH RIVER PLANT; STORAGE FACILITIES; TANKS; ULTRASONIC WAVES; VITRIFICATION; WASTES; | |
DOI : 10.2172/1043694 RP-ID : SRR-STI-2012-00346 PID : OSTI ID: 1043694 Others : TRN: US1203289 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2011 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2011 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2011-00026, HLW Tank Farm Inspection Plan for 2011, were completed. Ultrasonic measurements (UT) performed in 2011 met the requirements of C-ESR-G-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 25, 26 and 34 and the findings are documented in SRNL-STI-2011-00495, Tank Inspection NDE Results for Fiscal Year 2011, Waste Tanks 25, 26, 34 and 41. A total of 5813 photographs were made and 835 visual and video inspections were performed during 2011. A potential leaksite was discovered at Tank 4 during routine annual inspections performed in 2011. The new crack, which is above the allowable fill level, resulted in no release to the environment or tank annulus. The location of the crack is documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.6.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190002700LZ | 479KB | download |