科技报告详细信息
| Measure Guideline. Internal Insulation of Masonry Walls | |
| Straube, J. F.1  Ueno, K.1  Schumacher, C. J.1  | |
| [1] Building Science Corporation (BSC), Somerville, MA (United States) | |
| 关键词: BSC; mass masonry; masonry; insulation; interior insulation; freeze-thaw; retrofit; interior retrofit; spray foam; spray polyurethane foam; moisture management; water control; water shedding details; indoor air quality; combustion safety; airtightness; thermal performance; embedded wood members; | |
| DOI : 10.2172/1219736 RP-ID : DOE/GO--102012-3523 PID : OSTI ID: 1219736 Others : Other: 5891 |
|
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
This measure guideline provides recommendations for interior insulation assemblies that control interstitial condensation and durability risks; recommendations for acceptable thermal performance are also provided. An illustrated guide of high-risk exterior details (which concentrate bulk water), and recommended remediation details is provided. This is followed by a recommended methodology for risk assessment of a masonry interior insulation project: a series of steps are suggested to assess the risks associated with this retrofit, with greater certainty with added steps.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201704190002593LZ | 12558KB |
PDF