关键词: BSC; mass masonry; masonry; insulation; interior insulation; freeze-thaw; retrofit; interior retrofit; spray foam; spray polyurethane foam; moisture management; water control; water shedding details; indoor air quality; combustion safety; airtightness; thermal performance; embedded wood members; | |
DOI : 10.2172/1219736 RP-ID : DOE/GO--102012-3523 PID : OSTI ID: 1219736 Others : Other: 5891 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
This measure guideline provides recommendations for interior insulation assemblies that control interstitial condensation and durability risks; recommendations for acceptable thermal performance are also provided. An illustrated guide of high-risk exterior details (which concentrate bulk water), and recommended remediation details is provided. This is followed by a recommended methodology for risk assessment of a masonry interior insulation project: a series of steps are suggested to assess the risks associated with this retrofit, with greater certainty with added steps.