科技报告详细信息
Analysis on linac quadrupole misalignment in FACET commissioning 2012
Sun, Yipeng ; /SLAC
关键词: ALGORITHMS;    ALIGNMENT;    COMMISSIONING;    LINEAR ACCELERATORS;    QUADRUPOLES;    STANFORD LINEAR ACCELERATOR CENTER ACCPHY;   
DOI  :  10.2172/1045190
RP-ID  :  SLAC-TN-12-005
PID  :  OSTI ID: 1045190
Others  :  TRN: US1203655
学科分类:核物理和高能物理
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

In this note, the analysis on linac quadrupole misalignment is presented for the FACET linac section LI05-09 plus LI11-19. The effectiveness of the beam-based alignment technique is preliminarily confirmed by the measurement. Beam-based alignment technique was adopted at SLAC linac since SLC time. Here the beam-based alignment algorithms are further developed and applied in the FACET commissioning during 2012 run.

【 预 览 】
附件列表
Files Size Format View
RO201704190002464LZ 231KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:23次