【 摘 要 】
The efficiency comparison for measured and simulated responses of a 10B-lined proportional counter and a 3He proportional counter in a close, symmetrical geometry are presented. The measurement geometry was modeled in MCNPX to validate the methods used for simulating the response of both the 3He and 10B-lined tubes. The MCNPX models agree within 1% with the 3He tube measurements and within 3% for the 10B-lined tubes when a 0.75-??m boron-metal lining is used.