Final Technical Report for DUSEL Research and Development on Sub-Kelvin Germanium Detectors for Ton Scale Dark Matter Search | |
Cabrera, Blas | |
关键词: germanium particle detectors; cryogenic detectors; dark matter; | |
DOI : 10.2172/1050238 RP-ID : DOE/ER41480-1 PID : OSTI ID: 1050238 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
We have supported one graduate student and a small percentage of fabrication staff on $135k per year for three years plus one no cost extension year on this DUSEL R&D grant. There were three themes within our research program: (1) how to improve the radial sensitivity for single sided phonon readout with four equal area sensors of which three form a central circle and fourth a surrounding ring; (2) how to instrument double sided phonon readouts which will give us better surface event rejection and increased fiducial volume for future CDMS style detectors; and (3) can we manufacture much larger Ge detectors using six inch diameter material which is not suitable for standard gamma ray spectroscopy.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190001482LZ | 1064KB | download |