科技报告详细信息
Formed Core Sampler Hydraulic Conductivity Testing | |
Miller, D. H. ; Reigel, M. M. | |
关键词: Saltstone; Formed Core Sampler; Hydraulic Conductivity; | |
DOI : 10.2172/1056465 RP-ID : SRNL-STI--2012-00551 PID : OSTI ID: 1056465 Others : TRN: US1300203 |
|
学科分类:核能源与工程 | |
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190001355LZ | 422KB | download |