Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes | |
Cummings, James1  Withers, Charles1  Martin, Eric1  Moyer, Neil1  | |
[1] Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States) | |
关键词: drivers; air flow pathways; moisture transport; air infiltration; driving forces; duct system improvement; Building America; residential; residential buildings; | |
DOI : 10.2172/1219799 RP-ID : DOE/GO--102012-3480 PID : OSTI ID: 1219799 Others : Other: 5972 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
This report is a revision of an earlier report titled: Measure Guideline: Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes. Revisions include: Information in the text box on page 1 was revised to reflect the most accurate information regarding classifications as referenced in the 2012 International Residential Code. ???Measure Guideline??? was dropped from the title of the report. An addition was made to the reference list.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704190000006LZ | 7166KB | download |