Integration of the Uncertainties of Anion and TOC Measurements into the Flammability Control Strategy for Sludge Batch 8 at the DWPF
Edwards, T. B.
关键词: carbon;    oxalate;    formate;    nitrate;   
DOI  :  10.2172/1069092
RP-ID  :  SRNL-STI--2013-00139
PID  :  OSTI ID: 1069092
Others  :  TRN: US1300162
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Savannah River National Laboratory (SRNL) has been working with the Savannah River Remediation (SRR) Defense Waste Processing Facility (DWPF) in the development and implementation of a flammability control strategy for DWPF???s melter operation during the processing of Sludge Batch 8 (SB8). SRNL???s support has been in response to technical task requests that have been made by SRR???s Waste Solidification Engineering (WSE) organization. The flammability control strategy relies on measurements that are performed on Slurry Mix Evaporator (SME) samples by the DWPF Laboratory. Measurements of nitrate, oxalate, formate, and total organic carbon (TOC) standards generated by the DWPF Laboratory are presented in this report, and an evaluation of the uncertainties of these measurements is provided. The impact of the uncertainties of these measurements on DWPF???s strategy for controlling melter flammability also is evaluated. The strategy includes monitoring each SME batch for its nitrate content and its TOC content relative to the nitrate content and relative to the antifoam additions made during the preparation of the SME batch. A linearized approach for monitoring the relationship between TOC and nitrate is developed, equations are provided that integrate the measurement uncertainties into the flammability control strategy, and sample calculations for these equations are shown to illustrate the impact of the uncertainties on the flammability control strategy.

【 预 览 】
附件列表
Files Size Format View
RO201704180003781LZ 628KB PDF download
  文献评价指标  
  下载次数:26次 浏览次数:34次