科技报告详细信息
Acoustic Noise Test Report for the SWIFT Wind Turbine in Boulder, CO
Roadman, J. ; Huskey, A.
关键词: SWIFT WIND TURBINE;    ACOUSTIC NOISE TEST;    SMALL WIND TURBINE;    NREL;    Wind Energy;   
DOI  :  10.2172/1079096
RP-ID  :  NREL/TP-5000-58244
PID  :  OSTI ID: 1079096
学科分类:再生能源与代替技术
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report summarizes the results of an acoustic noise test that the National Renewable Energy Laboratory (NREL) conducted on the SWIFT wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 11: Acoustic Noise Measurement Techniques, IEC 61400-11 Ed.2.1, 2006-11. However, because the SWIFT is a small turbine, as defined by IEC, NREL used 10-second averages instead of 60-second averages and utilized binning by wind speed instead of regression analysis.

【 预 览 】
附件列表
Files Size Format View
RO201704180003523LZ 6382KB PDF download