科技报告详细信息
Report on Electrochemcial Corrosion Testing of 241-SY-102 Grab Samples from the 2012 Grab Sampling Campaign
Wyrwas, Richard B. ; Lamothe, Margaret E.
DOI  :  10.2172/1081319
RP-ID  :  LAB-RPT-13-00004 Rev 0
PID  :  OSTI ID: 1081319
学科分类:材料科学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50?��C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50?��C. The temperature would be lowered to 40 ?��C and the test repeated if the CPP curve indicated pitting corrosion at 50?��C. Ifno pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50?��C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50?��C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.

【 预 览 】
附件列表
Files Size Format View
RO201704180002919LZ 3028KB PDF download
  文献评价指标  