科技报告详细信息
Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Heating Season Energy and Moisture Levels
Vieira, R. ; Parker, D. ; Fairey, P. ; Sherwin, J. ; Withers, C. ; Hoak, D.
关键词: INFILTRATION;    BUILDING AIR LEAKAGE;    INTERNAL MOISTURE GAINS;    RESIDENTIAL;    RESIDENTIAL BUILDINGS;    BA-PIRC;    BUILDING AMERICA;    Buildings;   
DOI  :  10.2172/1096681
RP-ID  :  DOE/GO-102013-4041
PID  :  OSTI ID: 1096681
Others  :  Other: KNDJ-0-40339-02
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Two identical laboratory homes designed to model existing Florida building stock were sealed and tested to 2.5 ACH50. Then, one was made leaky with 70% leakage through the attic and 30% through windows, to a tested value of 9 ACH50. Reduced energy use was measured in the tighter home (2.5 ACH50) in the range of 15% to 16.5% relative to the leaky (9 ACH50) home. Internal moisture loads resulted in higher dew points inside the tight home than the leaky home. Window condensation and mold growth occurred inside the tight home. Even cutting internal moisture gains in half to 6.05 lbs/day, the dew point of the tight home was more than 15 degrees F higher than the outside dry bulb temperature. The homes have single pane glass representative of older Central Florida homes.

【 预 览 】
附件列表
Files Size Format View
RO201704180001554LZ 2792KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:27次