科技报告详细信息
Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program
Neuhauser, K.1  Gates, C.1 
[1] Building Science Corporation, Somerville, MA (United States)
关键词: retrofit;    deep energy retrofit;    der;    cost-effectiveness;    energy cost;    measured performance;    National Grid;    National Grid DER airtightness;    performance evaluation;    performance results;    building america;    residential;    residential building;    bsc;    Building Science Corporation;   
DOI  :  10.2172/1220906
RP-ID  :  DOE/GO--102013-3929
PID  :  OSTI ID: 1220906
Others  :  Other: 6610
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs and project objectives yielded a categorization of costs relative to energy performance objectives. On average about ?? of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.

【 预 览 】
附件列表
Files Size Format View
RO201704180000688LZ 20635KB PDF download
  文献评价指标  
  下载次数:24次 浏览次数:56次