科技报告详细信息
Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates
Fallahi, A.1  Durschlag, H.1  Elliott, D.2 
[1] Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States);Fraunhofer Center for Sustainable Energy Sys
关键词: Fraunhofer;    radiation control;    attics;    retrofit strategies;    radiant barrier;    residential;    residential buildings;    Building America;   
DOI  :  10.2172/1260915
RP-ID  :  NREL/SR--5500-58714
RP-ID  :  DOE/GO--102013-3943
PID  :  OSTI ID: 1260915
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

【 预 览 】
附件列表
Files Size Format View
RO201704180000351LZ 2392KB PDF download